Gamma4

Hip Fracture Nailing System

Available in three sizes, short, intermediate and long

DOWNLOAD THE BROCHURE
Cephalomedullary nailing system for the treatment of intertrochanteric fractures as well as a wide range of proximal femur fractures and associated femoral shaft fractures.

When it really matters,

Every advantage counts

Just like all other top-class professionals, you face critical decisions every day, striving to help rebuild lives as effectively and efficiently as possible, always relying upon next level tools and information.  At Stryker, we make continuous, often small enhancements to our processes and products which, when added together, can make all the difference to our customers’ performance and their patients’ lives.

Trochanteric Nail surgical animation

The Gamma4 Trochanteric Nail is a hip fracture solution for treatment of fractures in the intracapsular, trochanteric, subtrochanteric and shaft regions of the femur (including osteoporotic and osteopenic bone).

Redefined nail design

Pre-inserted and cannulated set screw

SOMA designed1

Length dependent Radius of curvature (RoC) Long Nails. 75-1.351

Chamfered distal tip

Shortened proximal body by 5mm compared to Gamma3

Wide distal diameter range: 9, 10, 11, 12, 13 & 15mm

Streamlined workflow

Precision Pin™ 3.9mm, has a drill tip with 5mm threads

Measure to the tip of Precision Pin™

The Precision Pin™ with its larger diameter reduces the likelihood of deflection/skiving by 66% compared to a standard k-wire1

The reduced pin deflection facilitates lag screw placement centrally through the nail according to the pre-planned trajectory, decreasing the risk of implant notching due a deflected pin2

Integrated instrument platform

We have a streamlined portfolio where we utilize the existing IMN Basic set

All nails have a dedicated distal targeting device

Reduced inventory

Lag Screw measurement off Precision Sleeve™

Single Lag Screw Driver

RC Lag Screw

When rotational stability and fixation performance is desired, the RC Lag Screw may be used4

Consists of three parts: RC Lag Screw, U-blade and U-blade end cap

When assembled, the width of the tip increases to 12.5mm instead of 10mm due to the spread of the U-blade

Anti-rotation system

Designed to provide stability in rotationally unstable femoral neck fragments

Provides temporary fixation of the femoral head during reaming and Lag Screw insertion

Discover Gamma4

Want to learn more? Fill in your details to download your Operative technique brochure.

Get brochure

Stay in touch

Be the first one to hear about Gamma4 updates in Europe.

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.